Treatment method for leakage or leakage inside the shut-off valve

For the shut-off valve, the external leakage is still handled well. For the middle flange leakage, tighten the bolt of the middle flange. If it is not enough, open it to see if the flange gasket is damaged. Leakage, it is necessary to close the packing gland. If the packing is too loose, it is necessary to add the packing. If it is directly leaking on the body, it can be welded under low pressure. If it is high pressure, give it up directly, safety first, for the internal leakage problem. The situation is not sure. First, it may not be closed, and then shut down with force. Second, the valve seat seal is damaged. This will be re-grinding. If the valve core is damaged, it depends on whether it is damaged by the medium or damaged by the medium. , but both must re-weld the sealing surface.

The internal leakage is generally damaged by the valve seat or the sealing surface of the valve core. This can grind the valve seat or the sealing surface of the valve plug. However, there is an special case that if the electric or pneumatic is used, the valve stroke may not be set. The external leakage depends on what is leaking. If the valve body leaks, it can only change the valve.

If there is an internal leak, there should be a problem with the sealing surface.

If the leak occurs, the valve is different and the leak position is different.

If the packing leaks outside, if it is tight or replace the packing, we often use the pressure plugging to stop the parking.

There are many leak points in the shut-off valve. In most cases, the leak is leaking from the gland. When the gland is opened or replaced, the gland should be replaced and the gland should be tightened. The internal leakage is that the sealing surface on the inside of the valve core is broken, but the actual experience tells us that sometimes the internal leakage may be stuck on the valve core, causing internal leakage. The specific treatment method is to open and close the valve. It is enough to wash away the hard objects several times. If it is a problem with the valve itself, choose the right time to replace the valve.

Global hardware network

Concerned about surprises

Label: Treatment method for leakage or leakage of the shut-off valve

Previous: Practical analysis of anti-static floor Next: Hardware instrument tools commonly used in precision measurement

Magnetic Chamfer is fabricated by steel and strong Neodymium Magnet,this magnetic chamfer is been used on concrete framing to form triangle and trapezoid edges or notches.There are strong neodymium magnets  in the chamfer thus using the chamfer strip do not need any nails or screws.Magnet chamfers have various of sizes which  to meet  different requirements of  the architecture designs and concrete constructions. Surface of the magnet chamfer is simply surface treated thus it is not anti corrosion and waterproof, please carefully clean the magnetic chamfer and keep it in a dry situation after the use. Magnetic chamfer strip is a quite necessarily tool in the concrete constructions.

There are two sort of magnet chamfers, trapezoid magnet chamfer and Triangle Magnet Chamfer,Trapezoid Magnetic Chamfer,also known as trapezoid shaped Magnetic Steel Chamfer or magnet steel chamfer,is a steel strip that configured with strong neodymium magnets.It have strong magnetic forces that usually been used on metal concrete formworks.

Triangle magnet chamfer is widely been used on concrete formwork.The triangle magnetic steel chamfer usually used to form triangle shaped corners or edges.we could supply multiple sizes of triangle magnetic chamfers, please kindly inform us the dimansions and quantity for calculate the cost.

Permanent MagnetsMagnetic ChamferMagnetsMagnetic Chamfer


Magnetic Chamfer

Magnetic Chamfer,Magnetic Steel Chamfer,Trapezoid Magnetic Chamfer,Triangle Magnet Chamfer

NINGBO SHINE MAGENETIC TECHNOLOGY CO.,LTD , https://www.shinemagnets.com

This entry was posted in on